Skip to content

Power conversions

Electrical Power Calculator (P = V × I)

Solve watts, volts or amps for DC or balanced AC circuits.

Circuit

1500 watts at 120 volts, single-phase, is 12.5 amps. DC power is volts times amps. Single-phase AC also uses the power factor. Three-phase uses line-to-line volts and the square root of 3.

PowerPOWER
1500 W

Solved power value

Show steps
Solve for
Watts
Watts
1500 W
Volts
120 V
Amps
12.5 A
Circuit
Single-phase AC
Power factor
1
  1. Circuit is single-phase AC.
  2. Power = 12.5 × 120 × 1 = 1500 W.

Estimate only. Check equipment labels and local code.

P = V × I

How to use this calculator

  1. Pick watts, volts, or amps as the unknown.
  2. Type the other two.
  3. Choose DC, single-phase AC, or three-phase AC.
  4. For AC, set the power factor.
  5. Submit the form if JavaScript is off. The same formulas run on the server, so the first number is already on the page.

The default is 12.5 amps at 120 volts, single-phase, power factor 1. Power is 1500 watts. That is the same pair as the watts-to-amps default, solved in the other direction. Change the solve-for box to amps and type 1500 watts at 120 volts. You get 12.5 amps back. The three numbers stay together on the card.

This page is the general power tool. The dedicated conversion pages always solve one way. Use those when you know you only need watts from amps, or amps from watts. Use this page when you are not sure which quantity is missing.

Formula

DC: P = V × I

P=V×I

Single-phase AC: P = V × I × PF

P=V×I×PF

Three-phase AC: P = √3 × V × I × PF

P=3×V×I×PF

P is real power, V is voltage, I is current, and PF is power factor. The DOE Fundamentals Handbook gives P = V × I for DC and P = VRMS × IRMS × PF for single-phase AC. For balanced three-phase wye or delta loads, DOE Volume 3 gives P = √3 × VLL × Iline × PF. The form selects among these models; unbalanced three-phase loads are not calculated.

Solving for watts

Watts are the product. On DC that is volts times amps. On single-phase AC the power factor is in the product. On three-phase the square root of 3 is in the product as well, and the volts must be line to line. The default 12.5 times 120 times 1 is 1500 watts. At a power factor of 0.8 the same current and voltage are 1200 watts, because only part of the current does real work.

Type 10 amps, 240 volts, single-phase, power factor 1. The engine returns 2400 watts. That is a round 2400 watt check. It is not a nameplate. If the nameplate lists kilowatts, multiply by 1000 first or use kW to amps .

Solving for current

Current is watts divided by the voltage term. On DC that is watts divided by volts. On single-phase AC, divide by volts times power factor. On balanced three-phase, also divide by the square root of 3. A hypothetical 1500 watts at 120 volts and power factor 0.8 gives 15.625 amps. Changing power factor to 1 describes a different operating condition and gives 12.5 amps; neither result selects wiring.

Solving for volts

Volts are watts divided by the current term. The result must land between 1 and 1000. An unsupported result is rejected; the page keeps the submitted inputs and marks the result unavailable instead of presenting a default answer as the result. Three-phase volts from this form are line to line, not line to neutral.

DC, single-phase, and three-phase

Direct current has no power factor. The DC choice ignores whatever factor is typed, and the steps say so. Single-phase is the US wall-outlet case at 120 V, or 240 V hot to hot. Three-phase needs the line-to-line voltage. A 208 V panel is 120 times the square root of 3, but this page does not convert 120 to 208 for you. Type the voltage you are actually using.

Ohm's law on this site models one ideal ohmic resistor on steady DC. Its result does not establish an AC operating point. AC current or voltage needs the compatible real electrical input power and power factor for that AC operating condition.

Watts at 120 V and 240 V

Single-phase, power factor 1. Every cell is computed by the same function as the result card.

AmpsWatts at 120 VWatts at 240 V
1 120 240
5 600 1200
10 1200 2400
12 1440 2880
15 1800 3600
16 1920 3840
20 2400 4800
24 2880 5760
30 3600 7200
40 4800 9600
50 6000 12000

Watts, volt-amperes, and the nameplate

Use real electrical input watts at the stated operating condition. Convert input kilowatts by multiplying by 1000. Apparent volt-amperes or kVA belong in the separate apparent-power formula; they are not input watts unless power factor is 1. A mechanical-output rating does not establish electrical input. Do not guess a missing power factor or combine label values from incompatible operating conditions.

The three-phase fixture on this site is 10 amps at 208 volts, power factor 0.9. Power is 3242.3991 watts. Amps to watts prints the same number, because both pages use the same product: current, times the square root of 3, times line-to-line volts, times the power factor. If your panel is 208 volts line to line, type 208. Do not type 120 and expect this form to convert it.

A 1500 watt, 120 volt, power factor 0.8 case is 15.625 amps. At power factor 1 the same real power and voltage correspond to 12.5 amps. The next-step arithmetic link preserves power factor rather than assuming a different operating condition. Installation and equipment suitability require separate qualified assessment.

Common questions

How do I calculate electrical power?

Multiply volts and amps on DC. On single-phase AC, multiply by the power factor as well. On three-phase, include the square root of 3 and use line-to-line volts.

Is this the same as volts to watts?

When you solve for watts, yes, the engine is the same. This page can also solve for volts or amps from the other pair.

Does power factor change the watts?

Yes on AC when you start from current and voltage. A factor of 1 is the largest real power for those amps. DC does not use it.

How do I find amps from watts?

Set solve-for to amps. Type watts and volts. Or open watts to amps, which is that path with no extra fields.

Where does the wire size come from?

This page does not determine conductor size or protection. Its next-step link opens watts to amps with the same assumptions for another arithmetic check.

Limitations

This is a calculation aid, not a permit.

Next step: watts to amps

The watts-to-amps page starts with these watts, volts, circuit, and power factor. Use it when you want the current at a different voltage. Dedicated pages also exist for volts to watts and watts to volts if you always solve the same way.

Model: steady DC or sinusoidal AC. AC values are RMS; three-phase requires a balanced load, total input watts, line-to-line voltage and line current. Power factor must match the operating condition. Unbalanced loads and distorted waveforms are outside this model. This is arithmetic, not installation or equipment-selection advice.

It does not select a wire, breaker or generator, establish circuit capacity, or apply installation rules. Convert kilowatts to watts before entering a power value. Search engines should use the clean address of this tool.

Server-rendered results use the values in the request URL. Shared addresses may remain in browser history and server logs. Do not enter confidential information.

It is also not a motor starting-current tool and not a power-factor correction design. Apparent power in kilovolt-amperes has its own page. Real power in kilowatts has kW to amps. This form stays in watts, volts, and amps.

The address of a filled-in calculation includes the solve-for choice, the two known values, the circuit, and the power factor. Search engines should use the clean address of this tool. A filled-in address points its canonical link at the page with no query. The number on the card is the same either way, because the server computes it before any script runs.

Results are rounded to four decimal places. 12.5 amps at 120 volts is 1500 watts. Other pairs are not whole numbers. The table uses the same rounding. If you need more places for a lab measurement, this page is the wrong instrument. It is built for planning a circuit, then handing the watts and volts to the current check.

Keep the assumptions with the number. A watt figure without the volts, the amps, the circuit, and the power factor cannot be checked later. Show steps includes those items so a printed page still shows them. The print button hides the menu and the form. The steps stay.

Sources

  1. U.S. Department of Energy Fundamentals Handbook, Electrical Science, Volume 4. Accessed 2026-10-29.
  2. U.S. Department of Energy Fundamentals Handbook: Electrical Science, Volume 3. Accessed 2026-10-29.

Cite this page

Wattopedia Editorial Team. Electrical Power Calculator (P = V × I). https://wattopedia.com/power-calculator . Updated 2026-10-28.