ENERGY STAR chart, then NIST watts
How to use this calculator
- Measure the room in feet.
- Multiply length by width for square footage.
- Type that area.
- Mark whether the room is very sunny, heavily shaded, or neither.
- Type how many people regularly occupy the room. Mark kitchen if the unit cools a kitchen. The card applies the bound ENERGY STAR room guidance and converts the resulting thermal capacity to watts with the NIST International Table Btu per hour factor. This estimate does not establish the suitability of a particular unit or an electrical installation.
The default is 150 square feet, neither sun nor shade, two people, not a kitchen. The ENERGY STAR row for 100 up to 150 square feet is 5000 BTU per hour. No adjustment applies. Rounding down leaves 5000. Thermal watts are 5000 times 0.2930711, which is 1465.3555 W. The source assumes an 8 foot ceiling. The bound guidance does not quantify a higher-ceiling adjustment in BTU/h, so this form does not invent one.
Area must be from 100 to 2500 square feet. That is the span of the published chart. Below 100 or above 2500 the form rejects the query and shows the default. People are 1 to 20. Sun and kitchen are the four ENERGY STAR adjustments from the 2 February 2024 article How To Choose the Right Sized Window AC: shade minus 10 percent, sun plus 10 percent, 600 BTU per person over two, kitchen plus 4000 BTU, then round down to the nearest thousand.
Formula
chart BTU from ENERGY STAR square-foot row
adjusted = chart × sun factor + 600 × extra people + kitchen 4000
shop BTU = floor(adjusted / 1000) × 1000
Thermal W = cooling capacity in Btu_IT/h × 0.2930711
NIST Special Publication 811 Appendix B.9 lists the International Table Btu per hour to watt factor as 0.2930711. This page uses that factor rather than the thermochemical factor 0.2928751. The conversion preserves heat-flow capacity. It does not convert cooling output into electrical input or determine an appliance's efficiency.
The default case and the 147.5 example
ENERGY STAR works a rectangular room 14 feet 9 inches by 10 feet, which is 147.5 square feet, and says that room needs 5000 BTU. This engine agrees. 150 square feet sits on the inclusive upper bound of the first row, so it also reads 5000. A 10 by 15 room is 150 square feet. A 12 by 12.5 room is also 150. Both are the default.
Type 200 square feet. The row is 150 up to 250, which is 6000 BTU per hour. Watts are 1758.4266. Type 2500 square feet. The last row is 2000 up to 2500, which is 34000 BTU per hour. Watts are 9964.4174. Search snippets sometimes truncate that last cell as 34,00. The ENERGY STAR products page lists 34,000.
Worked adjustments
Keep 150 square feet and mark very sunny. The base capacity is 5000 BTU/h. Multiplying by 1.1 gives 5500 BTU/h; rounding down to the nearest thousand gives 5000 BTU/h. Thermal watts remain 1465.3555. This illustrates the source's rounding rule, not a claim about available products or the suitability of a unit.
Keep 150 square feet and mark kitchen. Chart 5000 plus 4000 is 9000. Rounding leaves 9000. Watts are 2637.6399. Keep 150 square feet and type 4 people. Two extra people add 1200 BTU. Adjusted 6200 rounds down to 6000. Watts are 1758.4266. Heavily shaded 150 square feet is 5000 times 0.9, which is 4500, then 4000 after rounding. This form will not apply sun and shade at once. They are opposite cases.
What bigger is not always better means here
ENERGY STAR warns that an oversized room air conditioner cools the room before it removes humidity, so the space feels damp. The chart is the sizing method this site uses. It is not a Manual J load. It is not a central air tonnage tool. One refrigeration ton is a different conversion, owned by a later page. Do not divide these BTU figures by 12000 on this form and call the result a permit.
For example, 5000 Btu_IT/h is 1465.3555 thermal watts. Those watts represent heat removed per unit time. The same cooling capacity can correspond to different electrical inputs for different equipment and operating conditions, so dividing this thermal value by supply voltage would not establish appliance current. No electrical-current handoff is provided.
How the capacity lookup works
The linked ENERGY STAR source contains the full room-area chart. This calculator looks up the single area band that matches your input, applies the published adjustments, and shows the result with its assumptions above rather than reproducing the complete source table here. The chart assumes an 8-foot ceiling; this calculator does not estimate a taller-room adjustment.
Common questions
How many BTU do I need for 150 square feet?
5000 BTU per hour on the ENERGY STAR chart when the room is not a kitchen, has two people, and is not called very sunny or heavily shaded. Watts are 1465.3555.
Does 150 square feet use the 5000 or the 6000 row?
5000. This engine treats each ENERGY STAR "up to" as inclusive, so 150 stays on the first row. 150.0001 would move to 6000 if you could type that many digits. The form accepts four decimal places. 151 is 6000.
How do I convert BTU per hour to watts?
Multiply by 0.2930711. That is NIST IT Btu per hour to watt. 5000 times 0.2930711 is 1465.3555.
Should I round up?
ENERGY STAR says round down to the nearest thousand after adjustments. This page follows that note. Rounding up is not this engine.
Can I enter meters?
No. ENERGY STAR measures in feet. Convert inches to a fraction of a foot yourself. 9 inches is 0.75 feet on their article.
Limitations
This is a calculation aid, not a permit.
The converted watts describe thermal cooling capacity, not electrical input power. They cannot establish compressor current, energy cost or a branch-circuit requirement. Use the exact unit's electrical ratings for a separate electrical calculation.
It does not invent BTU per square foot as a single ratio. The ENERGY STAR rows are not 20 BTU per square foot at every size. 5000 divided by 150 is not the rule for a 1000 square foot room. Look up the row. It does not adjust for insulation, windows, or climate zone. Those are outside the four ENERGY STAR notes. It does not pick a SEER2 or a CEER. Find a certified model in the ENERGY STAR product finder after you have a shop size.
It does not size a whole-house heat pump. It does not convert watts to BTU for a space heater. That conversion page is Wave 2. It does not store what you type. Search engines should use the clean address of this tool.
The address of a filled-in calculation includes area, sun, people, and kitchen. A filled-in address points its canonical link at the page with no query. Keep the assumptions with the number. A BTU figure without the square footage and the four adjustments cannot be checked later. The print button hides the menu and the form. The steps stay.
A separate cost estimate needs the appliance's electrical input over its operating period or measured electrical energy. The thermal watts on this page cannot supply that input. Keep cooling capacity, electrical power and energy consumption distinct.
Sources
- ENERGY STAR, Room Air Conditioners: cooling-capacity table and sizing guidance. Accessed 2026-10-19.
- ENERGY STAR, How To Choose the Right Sized Window AC. Accessed 2026-10-19.
- NIST Guide to the SI, SP 811, Appendix B.9: heat-flow conversion factors. Accessed 2026-10-19.
The bound ENERGY STAR references supply single-room capacity guidance, adjustments and rounding. The bound NIST SP 811 Appendix B.9 reference supplies the International Table Btu/h-to-watt factor. These references do not supply a particular unit's electrical input, current or installation requirements.
Cite this page
Wattopedia Editorial Team. BTU calculator. https://wattopedia.com/btu-calculator . Updated 2026-11-15.