Capacitance tools
How to use this calculator
- Choose Code to interpret three digits using the documented picofarad convention below.
- Choose Series or Parallel to find an ideal equivalent capacitance from two or three values.
- Network inputs are in microfarads.
- Set the third value to zero to omit it.
- The result also shows nanofarads and picofarads.
The default code, 104, is a KEMET example for the product families named in its datasheet. Under that convention it represents 100,000 pF, or 100 nF, or 0.1 µF. This is not a universal decoder: markings differ among products. Confirm the complete marking with the exact component datasheet before relying on it. This form reads only the three digits and does not interpret other characters.
Three-digit example
pF = (10 × digit1 + digit2) × 10^(zeros)
In this documented convention, the first two digits are significant figures and the third digit gives the number of zeros in picofarads. The form accepts multiplier digits from zero through six. It does not implement the source's special digit-nine case. Divide pF by 1,000 for nF, then by 1,000 again for µF. SI prefixes scale the unit; they do not change the quantity.
Series and parallel values
For an ideal parallel combination, add the capacitances. For an ideal series combination, add their reciprocals and take the reciprocal of that sum. These are the basic DC-network relationships described in the DOE Fundamentals Handbook. For example, 1, 5, and 8 µF in parallel total 14 µF. In series they produce about 0.7547 µF; this calculator rounds to four decimal places.
The form accepts values from 0.0001 to 10,000 µF. Zero for the third input means “omit that input,” not a physical component. This tool handles one series or parallel group at a time. It does not solve mixed networks, component voltage ratings, tolerance, temperature effects, or circuit behavior.
Convert between pF, nF, and µF
The displayed units describe the same capacitance at different scales. One nanofarad is 1,000 picofarads, and one microfarad is 1,000 nanofarads. To move from pF to nF, divide by 1,000. To move from nF to µF, divide by 1,000 again. Moving in the opposite direction means multiplying by 1,000 at each step. These are decimal SI prefixes, so the conversion is a power-of-ten scale change rather than a different electrical quantity. The result card shows all three forms so you can check the scale without doing the conversion separately.
For example, 100,000 pF is 100 nF and 0.1 µF. The number changes because the unit changes; the underlying capacitance does not. A value that looks small in microfarads can be easier to compare with a marking written in picofarads when both units are shown together. Keep the unit beside the number when copying a result into notes. A bare number without pF, nF, or µF is ambiguous and can be off by a factor of 1,000 or more.
Worked series example
Suppose the selected values are 1 µF, 5 µF, and 8 µF, and the solve mode is Series. The ideal equivalent is the reciprocal of the sum of the reciprocals: 1 ÷ (1/1 + 1/5 + 1/8) µF. The reciprocal terms add to 1.325 per microfarad, and taking the reciprocal gives approximately 0.7547 µF. The answer is lower than the smallest entered capacitance, which is a useful arithmetic check for this ideal series model. The tool carries extra precision through the calculation and rounds the displayed result to four decimal places.
If the third input is zero, it is omitted from that sum. It is not treated as a zero-capacitance component, because a reciprocal of zero is undefined. The result therefore describes the two entered positive values in that case. To compare a different pair, change the inputs and select Calculate. Read the selected mode and the values printed in the result steps before comparing two outputs. A familiar result from a different input set is not a substitute for checking the current values.
Worked parallel example
Use the same 1 µF, 5 µF, and 8 µF inputs in Parallel mode. The ideal equivalent is the direct sum: 1 + 5 + 8 = 14 µF. The result is larger than any one of those entered values, which is the expected relationship for the stated ideal parallel model. The calculator reports 14 µF, 14,000 nF, and 14,000,000 pF so the scale is visible in each unit. These are alternate expressions of one calculated equivalent, not three separate component ratings.
The formula applies to a single parallel group. If a real network contains series sections and parallel sections together, the full network must be reduced section by section using the actual connections. This page does not read a schematic or infer which components share nodes. Do not combine values merely because the parts appear next to one another on a board or in a parts list. The wiring relationship is part of the model input, and the calculator only performs the one selected relationship.
Choose the calculation that matches the question
Use Code when you have a supported three-digit marking and need the capacitance represented by that code. Use Series when the values belong to a single ideal series group. Use Parallel when the values belong to a single ideal parallel group. The modes answer different questions, so confirm the selection before reading the result. In code mode, the digit selectors determine the result; in network modes, the capacitance inputs determine it. The page displays the steps used so that you can compare the answer with the selected inputs.
The code form accepts the first two digits from zero through nine and a multiplier from zero through six. That limit is a limitation of this tool, not a statement that all manufacturers use the same marking convention. The network form accepts positive capacitance values from 0.0001 to 10,000 µF for each included input. The third network value is optional and is omitted only when entered as zero. Inputs outside the supported range are rejected rather than silently converted or clamped.
Check a physical component marking
Before treating a code result as a part identification, compare the full marking and part number with the manufacturer information for that exact component. This page reads three digits only. It does not interpret letters, a tolerance character, a voltage suffix, a series name, or other text printed beside the digits. Similar-looking codes can have different meanings under a different product convention. The cited KEMET datasheet documents the described convention only for the product families it covers; it does not establish that convention for every capacitor sold by every manufacturer.
The same care applies when entering a measured or nominal capacitance. Confirm whether the number is stated in pF, nF, or µF, then choose or convert to the microfarad input unit used here. Do not infer missing digits from a photograph or assume a printed value is a measured value. This calculator does not identify a component, validate a substitute, or compare a measured part with an allowed tolerance. Those questions require the part's own documentation and measurement conditions.
Example codes
The table shows examples calculated by this tool under the documented KEMET marking convention. Use a component datasheet to confirm what a real marking means.
| Code | µF | nF | pF |
|---|---|---|---|
| 101 | 0.0001 | 0.1 | 100 |
| 102 | 0.001 | 1 | 1000 |
| 103 | 0.01 | 10 | 10000 |
| 104 | 0.1 | 100 | 100000 |
| 105 | 1 | 1000 | 1000000 |
Common questions
What does 104 mean on a capacitor?
For the KEMET product families in the cited datasheet, 104 means 100,000 pF, or 100 nF, or 0.1 µF. Confirm the marking against the exact component datasheet.
Do capacitors in series add?
The reciprocals add, then the result is inverted. This ideal calculation does not determine a component rating or approve a circuit.
Can I enter nanofarads?
Enter the capacitance in microfarads. For example, 100 nF is 0.1 µF.
Limitations
This is a calculation aid, not a permit.
Resistor color sits on the same electronics subject. Use it when the part is a resistor, not a capacitor. This card does not read resistor bands.
What the ideal network result leaves out
The series and parallel equations on this page are basic ideal network relationships. They use the capacitance values you enter and do not simulate a complete circuit. The result does not assess voltage rating, current, polarity, frequency response, losses, temperature, aging, tolerance, or operating environment. It does not estimate charge or stored energy, and it does not tell you how to handle or discharge a real component. Those properties are not inputs to these modes and are not supplied by the equivalent-capacitance calculation.
For a real design, identify the exact parts and circuit conditions before drawing a conclusion from an ideal equivalent. A number that is mathematically correct for the selected model can still be insufficient for an equipment decision because the model does not contain the missing product or circuit information. Use the manufacturer documentation for specifications and have application decisions reviewed by someone qualified to assess the complete circuit. The tool is intended to make the stated arithmetic transparent, not to approve a design or installation.
Limits
This is an educational arithmetic tool, not component-selection or safety advice. It does not interpret every manufacturer's code, determine voltage or tolerance, test a part, or establish whether a circuit is suitable. Check the exact component datasheet and have circuit decisions reviewed by a qualified person.
Sources
- U.S. Department of Energy Fundamentals Handbook, Electrical Science, Volume 2 of 4. Accessed 2026-10-20.
- KEMET ceramic capacitors, MIL-PRF-20 product datasheet. Accessed 2026-10-20.
- NIST Special Publication 330, The International System of Units (SI), Section 3. Accessed 2026-10-20.
The marking explanation is limited to the cited KEMET product families. Network formulas are limited to ideal series and parallel combinations. Unit prefixes follow NIST SI guidance.
Cite this page
Wattopedia Editorial Team. Capacitor. https://wattopedia.com/capacitor-calculator . Updated 2026-11-15.