VA = watts / power factor
How to use this calculator
- Type the real power of the load in watts.
- Type the power factor from the nameplate if you have it.
- Leave 1 if the load is resistive, or if you do not have a factor.
- The card returns volt-amperes.
- That is the apparent-power rating the inverter must at least meet. Submit the form if JavaScript is off. The same product runs on the server, so the first number is already on the page.
The default is an illustrative 1500 watts at power factor 1. Volt-amperes equal watts, so the result is 1500 VA. This is not a bundled appliance rating. An ideal resistive load has power factor 1; for actual equipment, use the nameplate. If a motor sheet says 0.8, type 0.8; 1500 divided by 0.8 is 1875 VA.
HyperPhysics states AC real power as volts times amps times power factor. Rearranged, volt-amperes equal watts divided by power factor. All About Circuits separates true, reactive, and apparent power the same way. This page does not add 25 percent because a vendor blog used 1.25 for continuous inverter loading. NEC 210.20(A) 125 percent is for overcurrent devices, not for inverter VA. Until a standard states a default continuous derate for this tool, the honest rating is VA from the formula.
Formula
VA = W / PF
Power factor must be from 0.1 through 1. Watts must be from 1 through 100000. At PF 1, VA equals watts. At PF 0.5, VA is twice the watts. 3000 watts at 0.9 is 3333.3333 VA on this engine. Shop an inverter whose continuous VA (or watts at PF 1, if that is how the sheet is printed) is at least that number. If the sheet only prints watts and assumes PF 1, compare watts to watts and know the assumption.
The default case
1500 VA. Next step carries 1500 watts, 120 volts, single-phase, power factor 1 into watts to amps, which is 12.5 amps. That current is for the AC load, not for the DC input of the inverter. Battery current is watts divided by battery volts and efficiency. Battery runtime already lets you type efficiency. This inverter page does not guess 90 percent.
Worked example
- For a hypothetical 1500 watt load with power factor 1, type 1500 and 1.
- The card prints 1500 VA.
- Compare that with the inverter's continuous rating, then check its manual for any load-specific restrictions.
- Open battery size if you need amp-hours for a number of hours, and watts to amps if you need the 120 volt current.
- Do not multiply 1500 by 1.25 by default. If the manual specifies an 80 percent continuous-loading limit, account for that separately and identify it as a manufacturer instruction, not a power-factor input.
A 746 watt load is 1 electric horsepower from NIST. At PF 1 the inverter need is 746 VA. At PF 0.8 it is 932.5 VA. The HP to kW page converts horsepower to kilowatts. It does not size inverters. Bring the watts here after that conversion if the motor sheet gives watts or after you convert kilowatts back to watts.
Watts at power factor 1
Each row is this engine at PF 1. 746 W is 1 electric horsepower.
| Watts | VA at PF 1 |
|---|---|
| 500 | 500 |
| 1500 | 1500 |
| 3000 | 3000 |
| 5000 | 5000 |
| 746 | 746 |
How this fits the power chain
Generator size is running and starting watts with no 1.25. Inverter size is VA with no 1.25. Battery size is amp-hours at typed depth of discharge and efficiency. Watts to amps is current for the AC side. Wire size follows current. Keep those steps separate. A 1500 VA inverter is not a 1500 watt generator and not a 1500 watt-hour battery.
If an inverter supplies a 1500 watt AC load at PF 1 and 120 volts, the load current is 12.5 amps. Branch-circuit loading is a separate question: the electrical-load page distinguishes a 15 amp circuit's nominal 1800 watts from a 1440 watt continuous-load value under its stated assumptions. Do not assume how long a real appliance operates; use its actual duty cycle and applicable instructions. This inverter page does not apply a branch-circuit adjustment.
Solar is a separate chain. Peak sun hours are NASA POWER GHI. Array kilowatts are daily kWh divided by those hours. Inverter VA is still watts divided by power factor. Do not type a US average of 5.5 peak sun hours here. There is no sun field on this form.
Modified-sine inverters may not run some motors and some electronics. That is a product choice, not a formula. This card will still print 1500 VA for 1500 watts. Read the inverter manual for motor lists. Do not treat VA as a guarantee that a given fridge will start. Starting watts belong on the generator page, and motor inrush belongs on the nameplate, not in a hidden inverter multiplier.
Surge ratings on inverter cartons are millisecond numbers. A 3000 watt peak for 0.1 second is not 3000 VA continuous. This card prints continuous apparent power from watts and power factor. If you need a motor to start, take starting watts to the generator page, then confirm the inverter manual lists that motor class. Do not add the carton peak to this VA and call it a new formula. Peak and continuous are different lines on the same nameplate.
DC input current is load watts divided by battery volts divided by inverter efficiency. At 1500 watts, 12 volts, and efficiency 1, that is 125 amps. Real inverters are below 1. Battery runtime lets you type that efficiency. This inverter page will not default 0.9. Cable size on the DC side follows that current, not the 12.5 amps on the 120 volt side. Mixing those two currents is a common mistake. Keep AC amps on watts to amps and DC amps on a later battery current step if we add one from a cited method.
Standby draw is another datasheet line. A 1500 VA inverter may draw tens of watts with no load. That idle power is not in this engine. Add it to the battery load if you care about overnight drain, and type the sum on battery runtime. Do not hide idle watts inside a 1.25 multiplier. Idle is a measured number or a sheet number, not a percentage of VA.
Know which power value you are entering
Watts and volt-amperes (VA) are linked, but they are not the same. Watts show active power. VA shows apparent power. The Department of Energy and NIST define the link with power factor. This tool starts with real watts and gives VA. Check that the watt value fits the load and the state you want to check. Do not put a VA rating in the watts box. If a label lists both, keep each value with its own unit.
Use a power factor that fits the load
Power factor links watts and VA. It is a ratio, not voltage or efficiency. For the same watts, a lower factor gives a higher VA result. Use a value from the product guide or a fit measurement for the state you are checking. The factor can change by product and use. Do not copy one from another load or pick one just to get a lower answer. If you do not know the right factor, treat the result as an example. Find good data before you compare real gear.
The watts-to-VA relationship
The formula is apparent VA = real watts divided by power factor. This follows from PF = watts / VA. Use it when you know both the load's real watts and its factor. It does not guess either value. For example, 1500 W at a factor of 0.8 gives 1875 VA. Also, 1000 W at 0.5 gives 2000 VA. These show the math only. They are not default values and do not stand for any appliance or inverter. Each result stays with its inputs, so you can check the math.
Read an answer with its inputs
A VA answer is hard to check without its watts and power factor. Keep the inputs beside the result. Make sure the watts are real AC power and the factor fits that same load and use. If a source gives a range or lists modes, note which one you chose. If it only gives a short label or does not say what it tests, do not fill in the gaps with data from another product. The math can still give an answer when an input is wrong. Check each value before you use it.
Compare the result with the exact inverter data
An inverter may list its steady watts, steady VA, peak power, output voltage, and heat limits. Compare the result with its VA limit. Compare the load's real watts with its steady watt limit. Check the current guide for the test state. A match in one column does not prove the other limit is met. Peak output is not steady output. This tool does not pick a model, add a safety margin, test startup, or prove a load will run. Use the exact maker's ratings and rules for any check.
A power calculation is not a system design
This page does not model motor start, compressor surge, peak time, wave shape, or which loads start at once. It does not know the inverter's DC input, battery limit, cable loss, heat, safety parts, or local rules. It does not pick a battery, fuse, wire, circuit, or inverter. A VA result cannot prove that a device will work or that a system is safe. Read the current guide for each model. Ask a skilled pro when you plan a setup or check a safety limit.
Keep inverter current and battery runtime separate
This result is apparent power on the AC load side. It is not battery-side current. To work out DC input current, you need the DC voltage. If you start with AC watts, you also need an efficiency value for that inverter and use. The inverter current calculator handles those inputs. A run-time estimate needs battery capacity, its rated voltage, the load, and clear limits for usable energy and efficiency. Use the battery runtime calculator for that math. Neither tool replaces the product guide or a real system check.
When a result should stay provisional
Keep the answer as an example if the factor is missing, the watt value is not real power, or the source does not say how it was tested. Do the same if the guide covers a broad product line, the heat is not the same, or the appliance's start needs are not known. A neat-looking answer cannot fix missing facts. Find the exact label and guide, ask the maker if a rating is not clear, and measure the load when fit. This tool shows the math. It cannot turn missing facts into a checked product rating.
Common questions
Does the result tell me which inverter to buy?
No. It converts the real watts and power factor you enter to apparent VA. It does not compare all limits for an exact inverter model.
Can I assume a power factor of one?
Only for an explicitly stated unity-power-factor example. Use documentation or a suitable measurement for a real load.
Limitations
This is a calculation aid, not a permit.
Watts to amps starts at this load, 120 volts, single-phase, with the same power factor. Use kVA to amps if you already think in kilovolt-amperes.
It does not add a 25 percent vendor margin. It does not size a charge controller. It does not size solar panels. Peak sun hours wait. It does not convert 12 volt input current. It does not pick modified sine or pure sine. It does not apply NEC 445.13. It does not store what you type. Search engines should use the clean address of this tool. It is not a permit. Waveform, surge milliseconds, and cooling still live on the inverter datasheet.
The address of a filled-in calculation includes watts and power factor. A filled-in address points its canonical link at the page with no query. Keep the assumptions with the number. The print button hides the menu and the form. The steps stay. Volt-amperes on the meter are a floor for apparent power, not a brand. If the carton prints only watts, compare at PF 1 and say so.
Sources
- U.S. Department of Energy Fundamentals Handbook, Electrical Science, Volume 3. Accessed 2026-10-14.
- NIST Handbook 130 – 2026, Section IV.B: Uniform Regulation for the Method of Sale of Commodities. Accessed 2026-10-19.
VA = W / PF is the relationship this calculator evaluates. The 1500 W default is illustrative, not a product or appliance rating. No 1.25 margin is stored in the engine.