An equipment grounding conductor gives fault current a path back to the supply. It links exposed metal parts to the grounding and bonding system.
Formula
This term describes a protective connection, so there is no single numerical formula that defines its role. OSHA's definitions identify the parts it connects, including equipment, raceways, and enclosures. The protective path is relevant when a fault energizes exposed conductive parts. Its effectiveness depends on the complete connection and the applicable protective arrangement, not just on the presence of a conductor with a familiar color.
Related quantities
| Conductor description | Role |
|---|---|
| Equipment grounding conductor | Connects normally non-current-carrying conductive equipment parts. |
| Grounded conductor | A circuit conductor intentionally grounded by the system design. |
| Grounding electrode conductor | Connects the grounding-electrode arrangement as specified by the system. |
Worked examples
For a conceptual example, a metal equipment enclosure and its ordinary load-current path serve different functions. The enclosure's protective connection addresses fault conditions, while the intended circuit conductors carry the normal load. A neutral is not automatically interchangeable with the equipment grounding conductor. Connections between these functions occur only as required by the applicable system design and rules. This explanation is not a wiring or testing procedure.
Reading a specification
When reading a diagram, follow the labels and identify which conductor performs each role. A grounding electrode, an equipment bond, and a grounded circuit conductor belong to a coordinated arrangement, but their names are not synonyms. OSHA's cited workplace requirements and definitions supply the scope for this page. Actual sizing, permitted connection methods, continuity requirements, and testing need the applicable rules and equipment instructions. Have a qualified electrical professional assess a real installation. This glossary deliberately provides no conductor size or protective-device pairing because the role definition alone cannot establish either.
Useful calculators
Read the wire-size calculator, ground-wire reference, and wiring tools only within their stated scopes. A load-conductor result should not be substituted for an equipment-grounding-conductor requirement.
Sources
- U.S. Occupational Safety and Health Administration, 29 CFR 1910.399, Definitions applicable to this subpart. Accessed 2026-10-20.
- U.S. Occupational Safety and Health Administration, 29 CFR 1910.304, Wiring design and protection. Accessed 2026-10-19.