Source-specific reference
These values apply only to the stated model, profile and conditions. They are not universal operating limits or compatibility approval.
- Model
- SPM041501200
- Description label
- 150 W, 12 V Mono
- Maximum power voltage (V)
- 18.2
- Open circuit voltage (V)
- 22.3
- Test irradiance w per m2
- 1000
- Test temperature (°C)
- 25
- Air mass
- 1.5
- Scope
- STC reference only; not an all-weather operating maximum, battery voltage or string design.
Read the two voltage columns separately
In the BlueSolar datasheet, maximum-power voltage and open-circuit voltage have separate columns. Open circuit describes the unloaded condition; maximum-power voltage refers to the stated power operating point. Neither column should be replaced by the voltage in the product description. The larger figure is not presented here as a universal maximum for the module in every environment.
The test conditions belong with the numbers
The table states STC: irradiance of 1000 W per square meter, temperature of 25 C, and air mass of 1.5. Those conditions are part of the rating. This source reference does not report your roof's output, a field measurement, or an all-weather voltage envelope.
Use an exact module record for further work
Record the article number and both voltage headings before comparing specifications. The related solar tools can organize entered nameplate values, but this page does not select an inverter, controller, battery connection, or series-string length. Those decisions need the full equipment limits and environmental design checks. A product label alone cannot supply them.
Sources
- Victron BlueSolar Monocrystalline Panels datasheet, SPM041501200 row. Accessed 2026-10-22.