kW = kWh / (PSH × efficiency)
How to use this calculator
- Type daily energy in kilowatt-hours.
- Type peak sun hours.
- Type efficiency from 0 through 1.
- Leave 1 if you do not have a loss fraction.
- The card returns DC array kilowatts. Submit the form if JavaScript is off. The same product runs on the server, so the first number is already on the page.
The default is 12 kWh at 4.7395 hours and efficiency 1. The 12 kWh input is an illustrative scenario, not a household estimate or an appliance claim. 4.7395 hours is Golden, Colorado NASA POWER annual GHI. Array kilowatts are 12 / 4.7395, which is 2.5319 kW. Efficiency 1 applies no additional loss factor. If you enter 0.86 as an explicit assumption, the result is 12 / (4.7395 × 0.86) = 2.9441 kW.
This calculator divides the daily energy you enter by the peak-sun-hour and efficiency assumptions you enter. It does not select a universal system-loss percentage or make a site-specific production forecast. Document the basis for any derating you choose, and avoid counting the same losses in both the hours and efficiency fields.
Formula
kW = kWh / (PSH × η)
Daily energy must be from 0.1 through 500 kWh. Peak sun hours must be from 1 through 10. Efficiency must be greater than 0 through 1. The card does not count modules. Divide kilowatts by module kilowatts from the sheet in your hand. A 400 W module is 0.4 kW. 2.5319 / 0.4 is 6.3297 modules. This site does not store 400 W as a default SKU.
The default case
2.5319 kW. Next step carries 12 kWh, 1 day, depth 1, and efficiency 1 into solar battery size, which prints 12 kWh of rated storage. Peak sun hours if you want Phoenix 5.8476 instead of Golden 4.7395. Inverter size is still a separate VA product for the AC load, not for the DC array rating.
Worked example
- You use 12 kWh per day in Seattle.
- Type 12, 3.4178, and 1.
- The card prints 3.511 kW.
- That is more array than Golden because Seattle GHI is lower.
- If you then type 0.86, the array grows again. Do not also derate the hours. Pick either GHI hours with eta 1, or GHI hours with a typed loss, not both plus a blog 20 percent.
A 746 W continuous load for 8 hours is 5.968 kWh. That is 1 electric horsepower from NIST, times 8 hours. At Golden 4.7395 hours and eta 1, the array is 1.2592 kW. HP to kW converts horsepower. It does not size arrays. Bring kilowatt-hours here after you know energy, not horsepower.
Daily energy at Golden hours
Each row is this engine at 4.7395 hours and efficiency 1.
| Daily kWh | Array kW |
|---|---|
| 6 | 1.266 |
| 12 | 2.5319 |
| 18 | 3.7979 |
| 24 | 5.0638 |
| 30 | 6.3298 |
How this fits the power chain
Peak sun hours are GHI. This page is array kilowatts. Solar battery size is storage kilowatt-hours. Inverter size is apparent power for an AC load. Generator size is running and starting watts. Keep those five products separate. A 2.5 kW array is not a 2500 W generator.
As a separate hypothetical, a 12 kWh load spread uniformly over 8 hours averages 1,500 W; at 120 V and power factor 1 that is 12.5 A. The array current is a DC number that depends on string voltage. This page does not print string current. Wire size still needs amps from the equipment sheet.
NREL PVWatts default system size is 4 kW DC in the online tool. That is a demo system, not a city sun figure and not this default. This default is 12 kWh over Golden GHI. Do not swap the 4 kW demo into the hours field.
Nameplate module efficiency, such as 20 percent, is not the eta field. Module efficiency is already reflected in the watts printed on the module. Eta here is an explicitly entered overall factor for the scenario; it is not preset to a universal soiling, wiring, inverter, or mismatch loss. Do not type 0.20 because a module ad said 20 percent efficient.
Net metering and time-of-use rates do not change kilowatts on this card. They change whether 12 kWh from the grid costs the EIA June 2026 residential rate. Open electricity cost for that price. This solar page does not store a rate.
A ground-mount versus a roof is orientation, not a second formula. If a survey gives plane-of-array hours, type those hours. If you only have GHI, use GHI and say so. Do not add 1.2 because a forum said tilt is 20 percent better. Cite the survey or keep GHI.
Common questions
How many solar panels do I need for 12 kWh per day?
You need 2.5319 kW DC at Golden hours and efficiency 1. Panel count is that kilowatt figure divided by the module kilowatts on your sheet. This card does not assume 400 W.
Should I type 0.86?
Use 0.86 only when it represents the explicit loss assumption for your scenario. Leave 1 for the raw energy-over-hours calculation. Do not hide a second derate inside the hours field.
Where do peak sun hours come from?
The peak sun hours page transcribes NASA POWER GHI for five cities. You may type any hours from 1 through 10 here if you looked up your own point.
Is this AC or DC kilowatts?
DC array size before inverter clipping. Inverter VA is watts divided by power factor on the inverter page. Do not treat 2.5319 kW DC as 2.5319 kVA.
Limitations
This is a calculation aid, not a permit.
Solar battery size starts at this daily energy, one day of autonomy, and full rated energy. Peak sun hours if you need a city lookup.
It does not invent a 400 W panel. It does not default 0.86. It does not run PVWatts hourly. It does not apply NEC 690. It does not size a charge controller. It does not pick string voltage. It does not store what you type. Search engines should use the clean address of this tool. It is not a permit. Shade, snow, and interconnection still live with the installer.
The address of a filled-in calculation includes energy, hours, and efficiency. A filled-in address points its canonical link at the page with no query. Keep the assumptions with the kilowatts. The print button hides the menu and the form. The steps stay. Array kW is a DC planning number, not a permit and not a module count.
Clipping happens when DC kilowatts exceed inverter AC kilowatts in bright hours. This card does not model clipping. If you already bought a 3 kVA inverter at PF 1, that is 3000 W AC, not a cap this engine applies. Size the array from energy and hours. Then compare to inverter VA on the inverter page. Do not fold clipping into eta unless your survey says to.
Snow loss is seasonal. PVWatts can include a snow model. This engine will not invent a Colorado snow fraction for Golden. If a month is buried, look up that month on POWER and type those hours, or type a lower eta from a cited snow study. A silent 10 percent snow cut would be the same class of guess as a silent 0.86.
Temperature coefficient on a module sheet describes how module power changes with cell temperature. This calculator does not model cell temperature or fold it into a default loss bundle. If you use an eta below 1, document which system effects it represents and avoid counting the same effect twice.
Sources
- NASA POWER annual horizontal solar resource, Golden, Colorado (NREL campus). Accessed 2026-10-19.
- National Laboratory of the Rockies, PVWatts V8 API documentation. Accessed 2026-10-16.
Array kW = kWh / (PSH × η) is the equation this calculator evaluates for the values you enter. Default hours come from NASA POWER's Golden horizontal GHI estimate. The 12 kWh input is illustrative, not a toaster-oven rating or typical household load; any efficiency factor is explicit rather than silently applied.
Cite this page
Wattopedia Editorial Team. Solar panel. https://wattopedia.com/solar-panel-calculator . Updated 2026-11-15.