| Real power W | A at 12 VDC | A at 120 VRMS, single-phase PF=1 | A at 240 VRMS, single-phase PF=1 |
|---|---|---|---|
| 10 | 0.8333 | 0.0833 | 0.0417 |
| 25 | 2.0833 | 0.2083 | 0.1042 |
| 50 | 4.1667 | 0.4167 | 0.2083 |
| 100 | 8.3333 | 0.8333 | 0.4167 |
| 250 | 20.8333 | 2.0833 | 1.0417 |
| 500 | 41.6667 | 4.1667 | 2.0833 |
| 750 | 62.5 | 6.25 | 3.125 |
| 1000 | 83.3333 | 8.3333 | 4.1667 |
| 1500 | 125 | 12.5 | 6.25 |
| 2000 | 166.6667 | 16.6667 | 8.3333 |
| 3000 | 250 | 25 | 12.5 |
| 5000 | 416.6667 | 41.6667 | 20.8333 |
How to read it
Start with real input power in watts. A cooking-output or motor-output label is a different quantity and cannot be substituted without the relevant input information. The DC calculation is current equals power divided by voltage. For single-phase AC, current also depends on power factor, so the displayed AC answers explicitly use unity power factor. The table rounds the result for readability; retain more precision in a calculation that will be used as an intermediate step.
What this chart is not
A wattage row is not a category average for equipment. It says nothing about the permitted number of connected products or the protective devices needed by an installation. The same real power can correspond to different AC current when power factor differs. These columns are not balanced three-phase results, and their voltage headings cannot be reinterpreted as line-to-line three-phase voltage. Likewise, an intermittent device's rated input is not its average consumption over the whole day.
Print and next step
Use the watts-to-amps tool when your exact wattage is between rows, when the voltage is different, or when you have a supported AC power-factor value. Preserve the input assumptions with a copied result. Check whether a measurement reports real watts or apparent volt-amperes before choosing a conversion. If only the latter is available, use an apparent-power relationship instead of relabeling it as real power.