| Pack | Nominal V | Charge min V | Charge max V | Recommended absorption V | Absorption time h | Float V |
|---|---|---|---|---|---|---|
| Cell | 3.2 | |||||
| 12.8 V (4 cells) | 12.8 | 14.0 | 14.4 | 14.20 | 2 | 13.5 |
| 25.6 V (8 cells) | 25.6 | 28.0 | 28.8 | 28.40 | 2 | 27.0 |
How to read the pack table
For the listed Victron Lithium Smart 12.8 V models, the manual gives a charge range from 14.0 to 14.4 V and a float value of 13.5 V. For its 25.6 V models, the range is 28.0 to 28.8 V and the float value is 27.0 V. These are manufacturer specifications for those models. The manual's installation section also recommends an absorption setting of 14.20 V for two hours on the 12.8 V models, and 28.40 V for two hours on the 25.6 V models. Its recommended float values are 13.50 V and 27.00 V. The absorption recommendation is one value within the model's charge range. It is not a separate universal range. Nominal voltage is the pack's rated voltage. It is not a charge target or a percent-full reading. This source does not give a state-of-charge curve or a resting-voltage table. The single-cell row has no charging values. The manual's pack data does not establish cell-level charger settings. Keep each column tied to its label: nominal, charge range, recommended absorption, absorption time, and float. Do not swap one for another. A chart can make a specification easier to scan, but it cannot replace the full manual or show every limit and operating condition.
What this table is not
This is not a universal LiFePO4 chart, a state-of-charge table, a resting-voltage guide, a temperature-compensation table, or a battery-capacity reference. The values apply only to the Victron Lithium Smart models described in the cited manual. Another battery with the same nominal voltage may have different charging rules. Never assume that its charge range or float value matches this chart. This chart does not list a low-voltage alarm, discharge cutoff, or safe operating limit. Do not infer any of these from a charge or float value. It also does not cover all pack sizes, accessories, or charger models. Check the source manual for its scope and the current manual for your exact product. If a product label or manual differs from this summary, follow the current manufacturer instructions.
Print and next step
Before changing a system, identify the exact battery model and read its current instructions. Check the battery management system requirements and the manual for the exact charger or inverter/charger too. Victron directs readers to the charger manual for device-specific settings. Do not copy these values to another brand or model. Do not use this chart as installation or safety advice. For runtime planning, use the battery's rated capacity and a separately supported load estimate. This chart contains neither. When comparing sources, check that the model, charging stage, voltage units, and conditions match. A familiar number without its context can lead to the wrong setting. Ask the battery or charger maker or a qualified professional if the instructions are unclear. The sources below support only the listed specifications; they do not certify a complete system or approve a particular charging setup.