| State of charge | Open circuit V |
|---|---|
| 100% | 12.73 |
| 90% | 12.62 |
| 80% | 12.50 |
| 70% | 12.37 |
| 60% | 12.27 |
| 50% | 12.10 |
| 40% | 11.89 |
| 30% | 11.81 |
| 20% | 11.66 |
| 10% | 11.51 |
How to read the 12v battery voltage chart
Trojan's 12 V column lists 12.73 V at 100%, 12.62 V at 90%, 12.50 V at 80%, 12.37 V at 70%, 12.27 V at 60%, 12.10 V at 50%, 11.89 V at 40%, 11.81 V at 30%, 11.66 V at 20%, and 11.51 V at 10%. Each row pairs a percentage of charge with a voltage from Trojan's flooded battery reference. Use the row as a comparison point under the stated test conditions. The voltage is an open circuit reading, not a value measured while a charger or load is active. The table gives selected reference points. It does not give a formula for values between rows, so this page does not estimate a percentage for an in between reading. The lowest listed point is the ten percent row. It should not be read as a battery failure test, a driving limit, or a promise of remaining runtime.
Measure under the listed conditions
Trojan says an accurate open circuit reading needs the battery to remain idle with no charging or discharging for at least six hours, preferably 24 hours. Disconnect loads before testing. A reading taken soon after driving, charging, or powering equipment is not under those stated conditions. Follow the battery maker's instructions for the meter and the test points. Keep metal tools away from both terminals at once, and do not allow a tool to bridge them. If the battery is damaged, leaking, unusually hot, or unsafe to handle, stop and seek qualified help. Flooded batteries contain electrolyte. Read the maker's safety guidance before opening or servicing one. This chart is only a reference for interpreting one manufacturer's open circuit table.
Know what this chart cannot tell you
This chart is specific to Trojan flooded batteries. It is not an AGM, gel, or lithium chart, and it should not be used as a general chart for all lead acid batteries. Another maker may publish different values or test conditions. The chart is not a charging guide, a loaded voltage limit, a battery health diagnosis, or a safe discharge recommendation. Voltage alone does not state how much usable energy remains in a particular battery or how long it can power a device. Battery age, temperature, model, load, and recent charging can all matter to a real measurement. For charging, maintenance, replacement, and use decisions, follow the current manual for the exact battery model and the equipment connected to it.
Choose the right next step
If your battery is a Trojan flooded model and you can meet the idle test conditions, compare its reading with the listed rows. If it is another chemistry or brand, find that maker's own reference instead. If the reading is between rows, record the measured value rather than assigning an unsourced percentage. If you need to estimate operating time, use a battery runtime tool only with the correct capacity and a suitable load estimate; this chart does not contain those inputs. If a measurement seems inconsistent with how the battery performs, have the battery tested using the manufacturer's recommended procedure. Do not use a resting voltage row by itself to decide that a battery is safe, healthy, fully charged, or ready for a particular job.