| Specification | Source-listed value |
|---|---|
| Source model: model | Little Giant WS30AM, item 620000, official English product page |
| Source model: full load watts (W) | 1,156 |
| Source model: voltage v AC | 115 |
| Source model: frequency (Hz) | 60 |
| Source model: phase | Single-Phase |
| Source model: full load current a | 10.4 |
| Source model: starting current a | 50.4 |
| Source model: control and duty | Piggyback Mechanical Float; Continuous Duty Yes. Duty capability is not an observed operating schedule. |
Calculate running cost
Enter electrical input watts from your appliance label or measurement. The reference does not establish a single running wattage.
Hours, days and rate start with the running-cost calculator's example, not your usage or tariff. Replace them with your own values. The result is in US dollars.
Little Giant identifies the WS30AM, item 620000, as a submersible effluent pump for transfer work that can include septic lines. Its ratings list 1,156 W at full load, 115 VAC and single-phase operation at 60 Hz. This is an example for an effluent-transfer role. Do not apply its rating to a grinder, an aerator or an unidentified pump in the same system.
Starting amps are a different electrical field
The manufacturer lists 10.4 A at full load and 50.4 A for starting. Neither current entry is a surge-watts figure. The page supplies no starting real-power trace or duration, so this reference leaves startup watts unknown. Its full-load watts also should not be renamed a constant draw across all water levels, pipe arrangements or operating points.
Continuous duty does not provide a dosing schedule
The ratings mark the pump as suitable for continuous duty, while the operation fields identify a piggyback mechanical float switch. A duty capability is not a record of how often the installed pump runs. Keep any operating log tied to the actual controls and observation period. The product page does not establish a household pumping schedule or the volume moved during each observed cycle.
Define what the system energy record includes
An effluent-pump rating does not account for every electrical component serving a treatment system. If a monitoring record includes controls, alarms or other treatment equipment, label that boundary before comparing it with a pump-only record. Cost estimates need energy over a stated interval and the applicable rate. This example supplies neither a total treatment-system energy allowance nor approval to select backup equipment or alter the installed controls.