| Specification | Source-listed value |
|---|---|
| Source model: model | Metabo Basic 250-24 W, order 601533180 |
| Source model: rated input (kW) | 1.5 |
| Source model: supply | 220-240 V, 50 Hz |
| Derived unit conversion: from (kW) | 1.5 |
| Derived unit conversion: factor | 1,000 |
| Derived unit conversion: result (W) | 1,500 |
| Derived unit conversion: meaning | Unit conversion only, not a new consumption measurement. |
Calculate running cost
Enter electrical input watts from your appliance label or measurement. The reference does not establish a single running wattage.
Hours, days and rate start with the running-cost calculator's example, not your usage or tariff. Replace them with your own values. The result is in US dollars.
Metabo's Basic 250-24 W page identifies order number 601533180 and a 220-240 V, 50 Hz supply version. Its technical table labels 1.5 kW as rated input power. Converting that unit gives 1,500 W, without creating a new measurement. The entry is a model-specific rating, not the consumption of every compressor with a similar tank.
Air delivery and electrical input are different
The same product page describes compressed-air delivery and tank capacity separately. Those quantities do not supply an electrical efficiency or a power curve for a connected air tool. Do not replace the rated input field with an output-power estimate derived from a promotional horsepower label. A comparison needs matching quantities and operating conditions, not just similar numbers on different machines.
Time under pressure needs its own record
A workshop observation should distinguish motor operation from time when the compressor is connected but not running. The product table does not provide separate electrical readings for those states or a start-current trace. Record the actual job and observation interval before estimating energy. A rated-input value alone does not say how much of that interval the motor operated.
Do not turn a consumption reference into sizing
The manufacturer describes a pressure switch and overload protection, but this page does not copy their operating procedure or turn them into supply recommendations. It cannot choose an extension lead, protective device, inverter or generator from the watt rating. For those decisions, use the exact equipment instructions and qualified local advice. Keep separately powered equipment outside a compressor-only energy total.
Sources
- Metabo Basic 250-24 W (601533180) compressor: technical details. Accessed 2026-10-22.